Model
|
AK-20V
|
AK-20H
|
|
Welding Power Source
|
220VAC and 440VAC+10%, -25%
|
|
Control Power Source
|
90~250VAC (Free Voltage)
|
|
Frequency
|
50/60Hz
|
|
Memory Retention
|
10 years and over after power failure
|
|
Indication
|
7-segment LED, 6.5mm(W) x 10.0mm(H)
|
|
External Input
(Dry contact or open collector)
|
Mode Switch1(MS1), Mode Switch2(MS2)
|
|
Start1(FS1), Start2(FS2)
|
|
Weld Trans or Thyristor Thermo Switch
|
|
External Contact Output
(250V 0.5A)
|
Solenoid Valve1, Valve2 : Control Voltage Output(90~250VAC)
|
|
Weld End Output : Relay Contact Output (1a1b), One Short(0.3sec)
|
|
Weld Current
|
Control Methode : Phase control by thyristor
|
|
Control Angle : 20~160
|
|
Maximum Analyze : 0.1% to 140 (0.14)
|
|
Weld Counter
|
0~3999 Counts
|
|
Program Parameters
|
|
|
|
|
Weld
Schedule :
|
0~9
schedules
|
|
|
|
|
Squeeze
time :
|
0~99
cycles
|
|
Up slope
time :
|
0~9
cycles
|
|
Weld
time :
|
0~99
cycles
|
|
Cool
time :
|
0~99
cycles
|
|
Off
time :
|
0~99
cycles
|
|
Weld
Current :
|
0.0~99.9%
|
|
|
|
|
|
Power Consumption
|
Control Power _ 12W Max. (Excluding valve output)
|
|
Ambient Temperature
|
-10 to 55¡É (at non-freezing status)
|
|
Storage Temperature
|
-25 to 65¡É (at non-freezing status)
|
|
Ambient Humidity
|
35% to 85% RH
|
|
Insulation Resistance
|
Min. 100M¥Ø (at500VDC)
|
|
Dielectric Strength
|
2000VAC 50/60Hz for 1 minute
|
|
Noise Strength
|
±2kV the square wave noise(pulse width:1§Á by the noise simulator) |
|
Dimensions
|
76mm(W)×194mm(H)×190mm(D)
3.0"(W)x7.6"(H)x7.5"(D)
|
194mm(W)×76mm(H)×190mm(D)
7.6"(W)x3.0"(H)x7.5"(D)
|
|
Weight
|
2.0Kg (4.4lb)
|